Specifications
| Connection Inlet Flange | DN 63 ISO-K |
| Connection Outlet Flange | DN 16 ISO-KF (NW16) |
| Cooling Method | Air Cooling (convection) Water Cooling Air Cooling (forced - fan) |
| Power Supply Voltage | DC 24V |
| Power Total Rated | 190.00 |
| Pumping Speed Air Nitrogen (@50Hz or max @default setting) | 0.065 |
| Pressure Ultimate | 2.000 × 10⁻⁸ |
TURBOVAC SL 80 C - DN 63 ISO-K / 16 KF
Part Number: 800002V3008
Variant
Explore the range of variants given below to compare the product
| Short Description | Part Number |
|---|---|
| 800002V3001 | |
| 800002V3002 | |
| 800002V3005 | |
| 800002V3006 | |
| 800002V3008 |
General Product Information
| Connection Cooling | 1/8" BSPP (G) Female |
| Connection Outlet Flange | DN 16 ISO-KF (NW16) |
| Connection Inlet Flange | DN 63 ISO-K |
| Cooling Method |
Air Cooling (convection)
Water Cooling Air Cooling (forced - fan) |
| Dimension Height | 0.145 |
| Dimension Length | 0.114 |
| Dimension Width | 0.095 |
| IP Rating | IP20 |
| Noise / Sound Level | 46.00 db(A) |
| Power Supply Frequency | DC Voltage |
| Power Supply Voltage | DC 24V |
| Weight | 1.90 |
| Dimension Comments | The dimensions length, width and height try to describe the outer shape of this particular product in its typical orientation when standing on the ground. We always recommend checking the detailed dimensions given in 2D drawings in the instruction manual or the 3D shapes given in 3D models. |
| Connection Inlet / Outlet Flange | DN 63 ISO-K | DN 16 ISO-KF (NW16) |
| Certification of Product | CE |
Performance Data
| Power at Ultimate | 17.00 |
| Power Total Rated | 190.00 |
| Pressure Ultimate | 2.000 × 10⁻⁸ |
| Pumping Speed Air Nitrogen (@50Hz or max @default setting) | 0.065 |
| Pumping Speed Argon | 0.060 |
| Pumping Speed Helium | 0.055 |
| Pumping Speed Hydrogen | 0.049 |
| Ramp Up Time | 90.00 |
| Nominal rotational speed | 1200.00 |
| Performance Comment | The compression of a TMP is a value describing how good the design can compress a gas type at special conditions. Compression data is measured only using the CF flange variants. The values are stated for all family members. For some pump classes we are stating different pumping speeds ISO > CF flange as small differences in geometry influence their performance leading to a difference >5%. |
| Gas Throughput Air Nitrogen Max | 0.200 |
| Gas Throughput Helium Max | 0.120 |
| Gas Throughput Max Hydrogen | 0.050 |
| Gas Throughput Argon Max | 0.160 |
Environmental Conditions
| Temperature Ambient Operation Max | 45.00 |
| Temperature Ambient Storage Max | 70.00 |
| Temperature Ambient Operation Min | 15.00 |
| Temperature Ambient Storage Min | -15.00 |
Classification
| Classification Dry or Wet Pump | Dry |
| Classification Product Pressure Range | High Vacuum: 1·10⁻³ - 1·10⁻⁷ mbar |
| Classification High / Medium / Rough Vacuum pump | High Vacuum Pump |
| Classification Vacuum Pump Technology | Turbomolecular Pump - full mechanical bearing |
Connectivity - Communication Interface
| Connection Electrical Comms Interface Connector | DSUB 15-PIN - Female |
Variants
| Installation Orientation | Any orientation |
Operation Conditions - Limitations
| Temperature Cooling Water Max | 40.00 |
| Temperature Cooling Water Min | 10.00 |
| Product Title | Part Number | Price | Add to cart |
|---|---|---|---|
| Turbo.Drive TD400 with USB | 800073V0008 | CHF 2,284.00 | |
| Turbo.Drive TD400 with RS485 | 800073V0003 | CHF 2,347.00 | |
| Turbo.Drive TD400 with RS232 | 800073V0002 | CHF 2,229.00 | |
| Cable Control - TD400 3m | 86440 | CHF 519.00 | |
| Cable Control - TD400 5m | 86450 | CHF 611.00 | |
| Cable Control - TD400 0.3m | 800152V0023 | CHF 379.00 | |
| Cable Control - TD400 0.4m | 800152V0022 | CHF 396.00 | |
| Cable Control - TD400 0.5m | 800152V0050 | CHF 403.00 | |
| Cable Control - TD400 2.5m | 86449 | CHF 484.00 | |
| Cable Control - TD400 0.2m | 800152V0021 | CHF 357.00 | |
| Water Cooling Unit - TURBOVAC SL 80 / TW 70 H | 800135V0001 | CHF 762.00 | |
| Air Cooling Unit - TURBOVAC SL 80 / TW 70 H | 800136V0001 | CHF 737.00 |